HVAC
Tighten loose low-voltage thermostat wires
A thermostat that drops out can have one loose conductor on the sub-base. This is the existing wires, not a new cable run.
Tools needed
- A small screwdriver
Materials
- A short piece of thermostat wire only if a conductor is actually broken
Steps
Turn off the breaker so a short does not blow the control fuse.
Pull the thermostat off the sub-base.
Tug each wire. If one is loose, strip about three-eighths of an inch, put it back in the same terminal, and tighten the screw.
Check the batteries if it has them, put the faceplate on, and restore power.
Safety notes
- Photograph the terminals before you disconnect anything. Do not let a short wire fall into the wall.
- If the display stays dead, a wire is broken in the wall, or the system still will not call for heat or cooling, call Fixer's.