A shutoff under a sink that weeps at the handle or will not stop the water can be replaced when it is a compression fitting on a sound copper stub. Soldered or threaded valves are a different job.
Tools needed
- Two adjustable wrenches
- A bucket
- Emery cloth
- A ferrule puller if the old ring is stuck
Materials
- A quarter-turn compression angle stop
- A new ferrule and nut
- A new supply line if the old one is worn
Steps
Shut off the house main and open a lower faucet so the line drains. Put a bucket under the valve.
Hold the valve body still. Loosen the supply-line nut, then the compression nut on the stub-out. Do not twist the copper.
Slide the old valve off. If the ferrule is stuck, pull it or cut it without scarring the copper. Do not reuse a scored ferrule.
Clean the stub, install the new nut and ferrule, and tighten about a half turn past hand-tight.
Reconnect the supply line, open the main slowly, and check the joint with a dry tissue.
Safety notes
- Confirm the valve is a compression fitting before you start. A soldered joint needs a different method.
- If the main will not close, the stub is bent or rotten, or the joint still weeps, call Fixer's.