Back to all guides

Electrical

Replace an outlet with a GFCI

A kitchen, bath, garage, laundry, basement, or outdoor outlet that is not GFCI-protected should not be replaced with a plain receptacle. This guide is that GFCI swap, on copper wire, after you know which cable is the incoming line.

Difficulty 3 of 5 · About 30–45 min

Tools needed

Materials

Steps

  1. Shut off the power at the breaker. Test the tester on a known live outlet, then confirm this outlet is dead.

  2. Identify the incoming LINE cable before you disconnect anything. Other cables are LOAD.

  3. If the wires are aluminum, stop. Put the device back with the breaker off.

  4. Land LINE hot and LINE neutral on the LINE terminals. Use LOAD only if you mean to protect outlets downstream. Cap unused LOAD wires if you do not.

  5. Mount the device, restore power, and press TEST, then RESET.

Safety notes

Rather have us do it? Book Fixer's Repair Service