Electrical
Replace an outlet with a GFCI
A kitchen, bath, garage, laundry, basement, or outdoor outlet that is not GFCI-protected should not be replaced with a plain receptacle. This guide is that GFCI swap, on copper wire, after you know which cable is the incoming line.
Tools needed
- A non-contact voltage tester
- Screwdrivers
- Needle-nose pliers
- Wire strippers
Materials
- A tamper-resistant GFCI of the correct amperage
- A weatherproof cover if the box is outdoors
Steps
Shut off the power at the breaker. Test the tester on a known live outlet, then confirm this outlet is dead.
Identify the incoming LINE cable before you disconnect anything. Other cables are LOAD.
If the wires are aluminum, stop. Put the device back with the breaker off.
Land LINE hot and LINE neutral on the LINE terminals. Use LOAD only if you mean to protect outlets downstream. Cap unused LOAD wires if you do not.
Mount the device, restore power, and press TEST, then RESET.
Safety notes
- Shut off the power at the breaker and prove the outlet is dead before you touch a screw.
- LINE and LOAD swapped is why a new GFCI will not reset. Do not use an indoor device outdoors.
- If the GFCI will not reset, the box is too small, the wire is aluminum, or you are not sure which cable is LINE, call Fixer's.