Plumbing repair
Fix a running toilet
If you hear water running long after a flush, the tank is refilling because water is slipping into the bowl, or the fill valve never gets the signal to stop. Most of the time the flapper or the float is the cause. You do not need to pull the toilet.
Tools needed
- A sponge or a small cup for water left in the tank
- A replacement flapper or canister seal that matches the flush valve
- Needle-nose pliers if the chain clip is stiff
Steps
Lift the tank lid off and set it where it cannot fall. Close the shutoff valve on the wall beside the toilet, then flush once so the tank empties.
Look at the flapper or canister at the bottom of the tank. If the chain is tight when the flapper is down, the seal cannot sit. Leave a little slack, about half an inch.
If the rubber is warped, cracked, or coated with grit, replace it. A 2-inch flapper will not seal a 3-inch flush valve. A tower or canister needs that same style, not a generic flapper. Some toilets need the brand's own flapper.
Open the shutoff a quarter turn and let the tank fill. The water should stop about an inch below the top of the overflow tube. Bend the float arm or turn the adjustment screw on a float cup until it does.
Flush and watch the flapper drop. It should seal and the fill should stop within a minute. If the toilet still runs, put a few drops of food coloring in the tank and wait 10 minutes without flushing. Color in the bowl means the flapper or the seat is still leaking.
If the fill valve will not shut off, or the supply connection drips, close the shutoff and call Fixer's.
Safety notes
- Shut off the water at the wall before you change the flapper. A tank lid is heavy and ceramic. Keep it off the floor where it can be kicked.
- This is a simple swap inside the tank. If the tank is cracked, the shutoff fails, or water is leaking onto the floor, call Fixer's.
- Do not use bleach tablets in the tank. They eat the rubber and the fill valve.
- If dye still shows up in the bowl after a flapper that matches the valve, or the fill valve runs at every float setting, call Fixer's.