Electrical
Cover an outdoor outlet
Tucson sun, dust, and a summer storm are hard on an outdoor outlet with a flat lid. The cover to use is an extra-duty in-use bubble cover on a weather-resistant (WR) GFCI. This guide is only that cover, on an outlet that is already a WR GFCI. If it is not, stop and call Fixer's.
Tools needed
- A non-contact voltage tester
- A screwdriver
- An extra-duty in-use bubble cover, with its gasket
- A dry rag
Steps
Turn off the breaker for that outlet. Confirm the outlet is dead with the tester. Tell anyone else in the house to leave that breaker alone.
Unplug everything. Remove the old cover screws and lift the cover off. Do not pull the outlet out of the box unless the new cover's instructions say the gasket sits behind the ears.
Read the outlet. If it is not marked weather-resistant (WR), stop and call Fixer's. If it is not a GFCI, and you cannot confirm the circuit is already GFCI-protected, stop and call Fixer's. A cracked face, burned slots, or a box full of mud is the same stop. The replacement to use is a WR GFCI with an extra-duty in-use bubble cover.
When the outlet is already a WR GFCI, set the new gasket flat and screw on the extra-duty bubble cover. Tighten until the gasket compresses evenly. Do not bow the plastic by overtightening one corner.
Turn the breaker on. Press the GFCI test button, then reset it. Plug a cord in, close the bubble cover over it, and confirm the lid shuts. Then unplug and confirm the lid still shuts on its own.
Safety notes
- Shut off the power at the breaker before you take the old cover off. A wet outdoor box is not a place to discover a live screw.
- If the outlet is not weather-resistant, or it is not a GFCI and you cannot confirm GFCI protection, call Fixer's. Use a WR GFCI with an extra-duty in-use bubble cover.
- After the cover is on, test and reset the GFCI. If the breaker trips, leave it off and call Fixer's. Do not keep resetting it.