HVAC
Clean a dirty furnace flame sensor
A furnace that lights and then shuts off can have a flame sensor coated with oxidation. A light cleaning is the try. Adjusting the gas valve is not.
Tools needed
- A quarter-inch nut driver or a screwdriver
Materials
- A fine abrasive pad, not coarse sandpaper
Steps
If you smell gas, do not go further. Leave and call for help from outside. Stop and call Fixer's before going further.
Turn off the furnace switch. Shut the gas valve at the furnace only if you can reach it safely.
Remove the burner door, find the thin rod with one wire, unplug the wire, and remove the screw.
Buff the rod gently, wipe it, and put it back in the same position. Restore power and gas only the way the manual describes, and watch one full start.
Safety notes
- Do not use coarse sandpaper. Do not bend the sensor into a burner. Do not adjust a gas valve or a gas fitting.
- If you smell gas, the furnace still shuts down after a careful cleaning, or you are not comfortable around the burners, stop and call Fixer's before going further.